Industrial Filtration Manufacturer · RO Pretreatment · SWRO · Power · Oil & Gas

OEM CROSS-REFERENCE AVAILABLE · 40″ & 60″ HIGH FLOW

Pall High Flow Filter Cartridge Replacement

Same fit. Same flow. Third-party verified filtration.

Industrial water treatment systems using Pall high-flow cartridges may face high replacement costs, extended delivery cycles or limited supply flexibility. Because cartridge geometry, filtration rating, flow direction and sealing details affect housing fit and process performance, a replacement should be selected through an engineering review rather than by nominal size alone. ECOFILTRONE supplies compatible high-flow filtration solutions for Pall HFU620, HFU640 and HFU660 references, supported by dimensional confirmation, seal verification, operating-condition review and sample testing. This process helps engineers and procurement teams establish a technically evaluated alternative while maintaining predictable maintenance planning and supply continuity.

Drop-in fit for existing housings Third-party tested filtration Direct factory pricing Free sample before you order

Pall HF660
Sound Familiar?

Why Engineers Evaluate Compatible Replacement Cartridges

Prices keep climbing

OEM cartridges cost 2–3× what the media is worth — and your filtration
budget stretches further every quarter.

Long, unreliable lead times

Waiting weeks for restocks risks downtime when a filter suddenly needs changing.

Worried a "generic" won't fit or last

The wrong OD or micron rating means por filtration, a fouled membrane
downstream, or a cartridge that won’t even seat in the housing.

Step 1 — Find Your Match

Brand Cross-Reference Table

Original ModelCompatible SolutionLengthDiameterMicron RatingSeal
Pall HFU620ECOFILTRONE Compatible Replacement20 inch6 inch nominal1, 5, 10, 20 or40 micrometres; selected to match the installed grade and process requirementDOE / SOE-222 / SOE-226
Pall HFU640ECOFILTRONE Compatible Replacement40 inch6 inch nominal1, 5, 10, 20 or40 micrometres; selected to match the installed grade and process requirementDOE / SOE-222 / SOE-226
Pall HFU660ECOFILTRONE Compatible Replacement60 inch6 inch nominal1, 5, 10, 20 or40 micrometres; selected to match the installed grade and process requirementDOE / SOE-222 / SOE-226
"Can a Replacement Really Match the Original?"

Engineering Compatibility Verification Process

The difference between a risky “generic” and a true engineered replacement.

A Cheap Generic Cartridge

✖  Approximate dimensions — may not seat or seal in your housing

✖  Unverified micron rating — inconsistent filtration

✖  Thin media that collapses under high flow

✖  No test data, no material certification

✖  Buy a full batch before you can test it

An EcoFiltrone Replacement

  Built to the original’s exact OD, length & end-cap configuration

Micron rating verified by bubble-point testing

High dirt-holding pleated media rated for full design flow

ISO 9001 factory · FDA-grade materials · test report with every order

Free sample first — validate the fit before you commit

Independently Tested. Not Just Claimed.

99.98%

removal efficiency at 3 μm (β5000)

Filtration eficiency verified by third-party laboratory testing to
DL/T 1866-2018, a filtration performance standard for high flow cartridges.
Rated β₅₀₀₀ at 3 μm (99.98% removal) and 99.9% removal at 2 μm.
Full test report available on request.

*Achievable SDI depends on your fed water. Share your water analysis and
our engineers will confirm the target before you order.

Why this matters for you

A replacement is only worth buying if it actually filters. Independent beta
ratio data means you can swap out OEM cartridges with confidence — the media
does the same job at a lower cost per change-out, and you have the test
report to show your process engineer.

Step 2 — Confirm the Specs

Technical Specifications

Length20" (508 mm) · 40" (1016 mm) · 60" (1524 mm) · custom
Outer Diameter6" (152 mm) · 6.5" (165 mm)
Micron Rating1 · 5 · 10 · 20 · 40 μm
Filter MediaPP · PES · PTFE · Glass Fiber
Max Flow RateUp to 110 m³/h per cartridge (60")
End Connections222 / 226 O-ring · bayonet · standard flat
O-Ring MaterialsBuna-N · EPDM · Silicone · Viton
Operating TempUp to 80°C (media dependent)
Max Differential Pressure3.5 bar @ 20°C
StructurePleated, high dirt-holding capacity

Why Engineers Choose ECOFILTRONE Replacement Solutions

Compatibility Review

Review existing cartridge models, dimensions and operating requirements before replacement.

Dimension Verification

Confirm length, diameter, end configuration and sealing details for proper installation.

Sample Testing Support

Provide sample verification to evaluate fit and filtration performance before bulk supply.

Long-term Supply

Support stable replacement supply with customized solutions and technical assistance.

Step 3 — GET YOUR QUOTE

How to Get Your Replacement

From your current model number to a fitted, cost-saving supply — in four steps.

1

Send Your Model

Share your current part number or specs.

2

Get Quote + Sample

We match it and send pricing within hours.

3

Test the Fit

Validate the free sample in your housing.

4

Order With Confidence

Approve, and we ship your full order.

Built for Demanding Applications

FAQ

ECOFILTRONE can provide compatible solutions for these Pall references, but interchangeability is confirmed for each project. The review covers overall dimensions, nominal diameter, end configuration, sealing interface, seal material, micron rating, flow direction and operating conditions. Supply should proceed after these parameters have been matched to the installed cartridge and housing.
Yes. Dimensions and interface details can be evaluated against drawing or physical sample, and DOE, SOE-222 and SOE-226 configurations are available. Seal options include EPDM, NBR, silicone and FKM/Viton. Customization remains subject to manufacturing review, chemical compatibility and the mechanical requirements of the existing housing.
Provide the complete original cartridge code, label photograph, process duty, upstream solids characteristics, downstream quality requirement and current operating performance. Available nominal options include1, 5, 10, 20 and40 micrometres. The selected grade should match the required retention basis and should not be inferred from cartridge length alone.
Lead time depends on quantity, cartridge length, micron rating, end configuration, seal material and whether a custom interface is required. ECOFILTRONE confirms the production schedule after the technical specification is approved. Standardized, forecast-based purchasing can improve supply continuity compared with unplanned replacement orders.
Yes. A sample can be supplied after the preliminary compatibility review. The recommended process is to verify dimensions and housing fit first, followed by a controlled operating trial that records initial differential pressure, flow stability, filtrate quality, service duration and final differential pressure. Acceptance criteria should be agreed before testing.
The review should include process fluid and chemical composition, operating and cleaning temperature, flow per cartridge, normal and maximum differential pressure, contaminant loading, required retention performance, housing configuration and planned change-out criteria. These parameters determine media, seal and structural suitability.

Don’t Miss Out!

Don’t Miss Out!