Table A — Micron Rating Selection by Application
| Application | Upstream Stage | Recommended Rating | Basis |
|---|---|---|---|
| SWRO guard filter | DMF | 5 µm nominal | Industry practice |
| SWRO guard filter | UF | 1–5 µm nominal | Industry practice |
| BWRO guard filter | DMF | 5–10 µm nominal | Industry practice |
| Condensate polishing | Demineraliser | 1–5 µm absolute | Process sensitivity |
| Pre-RO, high TSS | DMF (upset-prone) | 10–20 µm nominal, depth | Dirt holding priority |
Table B — Polypropylene Operating Limits
| Parameter | Typical Limit | Note |
|---|---|---|
| Max continuous temperature | 80°C (176 °F) | Rated, PP media and hardware |
| Max differential pressure | Per element spec, commonly 4–6 bar | Check manufacturer data sheet |
| Chemical resistance | Acids, alkalis, most inorganic salts | Verify against seal compound separately |
| Not recommended | Aromatic solvents, strong oxidisers | Replace PP with PVDF or PTFE media |
If you are working on a system specification, troubleshooting a performance issue, or looking for a compatible replacement, share your operating conditions and current cartridge details. ECOFILTRONE can review the application and suggest a suitable configuration.