Industrial Filtration Manufacturer · RO Pretreatment · SWRO · Power · Oil & Gas

Industrial Filter Cartridge Technical Resource Centre

Selection guides, performance troubleshooting and replacement references for engineers and procurement in water treatment, power and industrial process.

Selection guides, performance troubleshooting and replacement references
for engineers and procurement in water treatment, power and industrial process.

Table A — Micron Rating Selection by Application

ApplicationUpstream StageRecommended RatingBasis
SWRO guard filterDMF5 µm nominalIndustry practice
SWRO guard filterUF1–5 µm nominalIndustry practice
BWRO guard filterDMF5–10 µm nominalIndustry practice
Condensate polishingDemineraliser1–5 µm absoluteProcess sensitivity
Pre-RO, high TSSDMF (upset-prone)10–20 µm nominal, depthDirt holding priority

Table B — Polypropylene Operating Limits

ParameterTypical LimitNote
Max continuous temperature80°C (176 °F)Rated, PP media and hardware
Max differential pressurePer element spec, commonly 4–6 barCheck manufacturer data sheet
Chemical resistanceAcids, alkalis, most inorganic saltsVerify against seal compound separately
Not recommendedAromatic solvents, strong oxidisersReplace PP with PVDF or PTFE media

If you are working on a system specification, troubleshooting a performance issue, or looking for a compatible replacement, share your operating conditions and current cartridge details. ECOFILTRONE can review the application and suggest a suitable configuration.

Don’t Miss Out!

Don’t Miss Out!