Industrial Filter Cartridge Manufacturer

Industrial Pleated Filter Cartridges for Liquid Filtration

EcoFiltrone supplies pleated filter cartridges for industrial water, chemical, food and beverage, oil, pharmaceutical and process liquid filtration applications.

Available in polypropylene, PES, PTFE, nylon, PVDF, glass fiber and other filtration media, with multiple micron ratings, cartridge lengths, end-cap configurations and sealing materials.

  • Depth and membrane filtration options
  • Nominal and absolute-rated configurations
  • 10″, 20″, 30″ and 40″ cartridge lengths
  • DOE, 222 and 226 end-cap options
  • OEM and customized specifications available

Pleated Filter Cartridge Categories

Choose the right pleated filter cartridge based on filtration mechanism, contaminant loading and application requirements.

Pleated Depth Filter Cartridges

Prefiltration, high solids loading, downstream protection.

Pleated Membrane Filter Cartridges

Fine filtration, final filtration, controlled retention.

High-Capacity Pleated Filter Cartridges

Higher dirt-holding capacity, stable differential pressure, longer service life.

Select Pleated Filter Cartridges by Media

PP Pleated Filter Cartridges

General water, chemicals, pre-filtration.

PES Membrane Filter Cartridges

High flow, wide chemical compatibility.

PTFE Membrane Filter Cartridges

Aggressive chemicals, high-temperature applications.

Nylon Membrane Filter Cartridges

Strong and durable, suitable for organic solvents.

PVDF Membrane Filter Cartridges

Excellent chemical resistance.

Glass Fiber Pleated Filter Cartridges

High-temperature applications, viscous fluids, oil.

Pleated Depth Filters vs. Pleated Membrane Filters

Feature Pleated Depth Filter Pleated Membrane Filter
Main Function Remove bulk contaminants,
protect downstream filters
Precisely remove fine
particles and microbes
Filtration Mechanism Depth filtration through
porous structure
Surface (membrane)
filtration
Dirt-Holding Capacity High Lower
Retention Consistency Varies with loading Consistent and precise
Typical Position Prefiltration Final / Polishing filtration
Typical Materials PP, Polyester, Glass Fiber,
Cellulose, etc.
PES, PTFE, Nylon, PVDF,
etc.
Typical Applications High solids, coarse
filtration, protection
Fine filtration, sterile
filtration, critical fluids

Why Use Pleated Filter Cartridges?

Large Effective Filtration Area

Maximizes surface area for longer service life.

Low Initial Differential Pressure

Reduces energy consumption and operating costs.

Flexible Filtration Grades

Wide range of micron ratings and media choices.

Stable Particle Retention

Consistent filtration performance throughout service life.

Multiple Housing Configurations

Compatible with a variety of filter housings.

Pleated Filter Cartridge Applications

Industrial ro

Industrial Water Treatment

Remove suspended solids and protect downstream equipment.

Recommended Media: PP, PES

A large-scale SWRO plant with its complex piping and filtration systems

RO Pretreatment

Protect RO membranes from fouling.

Recommended Media: PP, PES

Chemical Processing

Chemical Processing

Clarify chemicals and process liquids.

Recommended Media: PTFE, PVDF

Food & Beverage

Ensure product quality and process reliability.

Recommended Media: PES

Pharmaceutical & High-Purity Processing

Critical filtration for high-purity fluids.

Recommended Media: PES, PTFE

Oil & Hydrocarbon Filtration

Remove particulates and protect equipment.

Recommended Media: Glass Fiber

Pleated Filter Cartridge Sizes and Configurations

Standard Cartridge Lengths

10 inch, 20 inch, 30 inch and 40 inch.
Custom lengths are also available.

End-Cap Options

DOE, 222/Flat, 222/Fin, 226/Flat, 226/Fin and custom options.

Seal Materials

EPDM, Silicone, FKM/Viton, NBR and PTFE-encapsulated seals.

Micron Ratings

Micron ratings vary according to the selected filter media and cartridge series.

How to Select the Right Pleated Filter Cartridge

Define the Filtration Stage

Identify the Liquid

Analyze the Contaminants

Confirm Retention Requirements

Review Operating Conditions

Check Housing Compatibility

Common Pleated Filter Cartridge Problems

Rapid Differential Pressure Rise

Caused by high solids loading, unsuitable filter media or an undersized filtration system.

Chemical Compatibility Failure

Filter media or sealing materials may degrade when exposed to incompatible chemicals or excessive temperature.

Short Service Life

May result from high contaminant loading, chemical attack or unsuitable operating conditions.

Cartridge Collapse or Deformation

Can be caused by excessive differential pressure, high temperature or improper installation.

Inconsistent Filtration Performance

May result from unsuitable media selection, bypass leakage or damaged filter cartridges.

Incorrect End Cap or Seal

Can cause leakage, bypass, poor housing fit and filtration system failure.

Manufacturing, Quality and Custom Pleated Filter Support

Media and Material Confirmation
Qualified raw materials with full traceability.

Pleating and Assembly Control
Consistent pleating, bonding and assembly processes.

Dimensional Inspection
Strict dimensional control for proper housing fit.

Performance Testing
Bubble-point, integrity, flow and pressure-drop testing as required.

Technical Documentation
COA, test reports and validation documents available upon request.

Customization Options
Custom media, sizes, end caps, seals and packaging.

FAQ

What is a pleated filter cartridge?

A pleated filter cartridge uses folded filter media to increase the effective filtration area within a compact cartridge structure. Depending on the media type, it can be used for prefiltration, clarification, fine filtration or final filtration.

Depth filters capture particles throughout the thickness of the filter media and usually offer higher dirt-holding capacity. They are commonly used for prefiltration and high-solids applications.

Membrane filters retain particles mainly through a controlled pore structure and provide more consistent filtration efficiency. They are generally used for fine, polishing or final filtration.

The correct filter media depends on the liquid type, contaminant characteristics, required micron rating, chemical compatibility and operating conditions.

Common options include:

  • PP for industrial water, RO pretreatment and general chemical filtration
  • PES for fine filtration of water-based and high-purity liquids
  • PTFE for aggressive chemicals, solvents and gas filtration
  • Nylon for compatible aqueous and solvent-based liquids
  • PVDF for high-purity and low-protein-binding applications
  • Glass fiber for high dirt-holding prefiltration
What is the difference between nominal and absolute filtration ratings?

A nominal rating indicates that the filter removes a stated percentage of particles at a specified size under defined test conditions.

An absolute rating represents a more controlled retention level at the stated particle size. The exact efficiency should always be confirmed according to the manufacturer’s test method and Beta ratio.


 

Common cartridge lengths include:

  • 5 inch
  • 10 inch
  • 20 inch
  • 30 inch
  • 40 inch

Custom lengths may also be available depending on the filter series and project requirements.

222 and 226 end caps use O-ring seals for more reliable installation and sealing inside the filter housing. They are commonly available with:

  • Flat closed end
  • Fin end
  • Spear end
  • Customized configurations

The correct end-cap type should be confirmed according to the existing filter housing.

Need Help Selecting a Pleated Filter Cartridge?

Please send us your application, liquid type, contaminant information, micron requirement, cartridge size, end-cap configuration, flow rate, temperature, pressure, and quantity.
Our filtration experts will recommend the best solution for you.

Don’t Miss Out!

Don’t Miss Out!